Specifications — MHR-5STP-2 Cable
UL NEC/
C(UL) CEC
UL AWM
Temp.
Standard
Lengths Weights
Shipping Conductor
Nominal
Core OD
Shielding
Materials
(% coverage)
Nom. DCR
Nominal
OD
Nominal
Capacitance
Nominal
Attenuation
Description
Nom.
Vel.
of
No.
of
Cond.
Nom.
Imp.
(ohms)
(stranding)
Diameter
Nom. DCR
Part No. (length)
Model
dB/
dB/
MHz
Prop.
Ft.
m
Lbs. kg
Inch mm
Inch mm
pF/ft pF/m
100 ft 100 m
Composite: (5) 26 AWG Miniature Coax • (2) 22 AWG Shielded Twisted Pairs • Coax Shielding: Aluminum Foil (100%) + Tinned Copper Serve
Nonplenum Cable • Gas-injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
26 AWG
(7/34)
0.019"
Alum. Foil
(100%)
5
coax
0.072 1.83
75
81%
16.7
54.8
500 152.4 42 19.1
304.8
Single:
22-175-02 (500')
22-175-03 (1000')
0.105 2.67
red, green, blue,
black, yellow
1000
83 37.6
Tinned Cu
Serve (95%)
-7.8
MHR-5STP-2
0.48 mm,
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
Tinned Cu
12.2 ohms/
1k ft,
40.0 ohms/
1 km
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
NEC CM
UL 1581
CSA FT-4
Sweep tested 5 MHz to 1 GHz.
66% 35 115
22 AWG
(7/30)
0.030"
Alum. Foil
(100%)
Single:
2
shielded
twisted
pairs
0.046 1.2
red and black,
green and white
conductor-
conductor
60 °C
17 ohms/
1k ft,
56 ohms/
1 km
0.76 mm,
Tinned Cu
62
203
Min. bend radius: 4.0"
17 ohms/
1k ft,
56 ohms
1 km
conductor-
conductor,
connected to
shield
Overall:
Overall
cable
0.400 10.2
gray
Plenum Cable • Gas-injected Foamed FEP Insulation • Fluorocopolymer Inner Jackets • Blue Fire-resistant PVC Outer Jacket
38
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
152.4
26 AWG
(7/34)
0.019"
Alum. in
Polyester Tape
(100%)
500
17.2
5
coax
0.074 1.88
75
81%
16.7
54.8
Single:
22-181-02 (500')
22-181-03 (1000')
0.102 2.59
red, green, blue,
black, yellow
1000 304.8 75 34.0
-7.8
MHR-5STP-2P
0.48 mm,
Tinned Cu
Serve (95%)
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
Tinned Cu
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
12.2 ohms/
1k ft,
40.0 ohms/
1 km
NEC CMP
UL 910
CSA FT-6
Sweep tested 5 MHz to 1 GHz.
66% 35 115
22 AWG
(7/30)
0.030"
Alum. in
Polyester Foil
(100%)
Single:
2
shielded
twisted
pairs
0.046 1.2
red and black,
green and white
with gray
fluorocopolymer
jacket
60 °C
conductor-
conductor
0.76 mm,
17 ohms/
1k ft,
56 ohms/
1 km
Tinned Cu
62
203
Min. bend radius: 7.0"
17 ohms/
1k ft,
56 ohms
1 km
conductor-
conductor,
connected to
shield
for each pair
Overall:
0.350 8.9
blue
02 December, 2008
|