Extron electronic Switch YCS SW2 User Manual

User’s Manual  
YCS SW2  
2 Input Transcoding Switcher  
Extron Electronics, USA  
1230 South Lewis Street  
Anaheim, CA 92805  
USA  
714.491.1500  
Fax 714.491.1517  
Extron Electronics, Europe  
Beeldschermweg 6C  
3821 AH Amersfoort  
The Netherlands  
+31.33.453.4040  
Fax +31.33.453.4050  
Extron Electronics, Asia  
135 Joo Seng Road, #04-01  
PM Industrial Building  
Singapore 368363  
+65.6383.4400  
Fax +65.6383.4664  
Extron Electronics, Japan  
Kyodo Building  
16 Ichibancho  
Chiyoda-ku, Tokyo 102-0082 Japan  
+81.3.3511.7655  
Fax +81.3.3511.7656  
68-1110-01 Rev. A  
09 05  
© 2005 Extron Electronics. All rights reserved.  
 
䄺ਞ  
ᅝܼ乏ⶹꢀꢀЁ᭛  
⬉⑤ꢀ嬦嫿⡈⌫倾Ề䑩ᷨ␂ᵋ㝈㕏䗅䑶㷑ɿꢀ嫿⡈⼆枼  
Ề䑩㙊♱一䗅Ờ䑶䰼丠Ờ䑶ɿꢀ䩭ᵊ㚢㕰  
⫊₩嫿㓾倾ᵎ䑩ㅗ崴弈ꢀɿ  
ꢀꢀꢀ䖭Ͼヺোᦤ⼎⫼᠋䆹䆒໛⫼᠋᠟
ݠ
Ё  
ꢀꢀꢀ᳝䞡㽕ⱘ᪡԰੠㓈ᡸ䇈ᯢDŽ  
ᢨᥝ⬉⑤ꢀᵻ⫊₩♱ḏ嫿⡈㈕㋊䑶㷑㈕㋊ㆁ㙊嫿  
⡈⍏ㅗ㞍暣䑶㷑䗅䑶㷑一Ḽẖ㋦ⅱⵃ䑶䰼丠䗅  
䑶㷑一ɿ  
ꢀꢀꢀ䖭Ͼヺো䄺ਞ⫼᠋䆹䆒໛ᴎ໇
ݙ
᳝  
ꢀꢀꢀ䴆ⱘॅ䰽⬉य़ˈ㾺⬉ॅ䰽DŽ  
⬉⑤㒓ֱᡸꢀ⣦Ⓟⵄ一澤ꢀ忀₎埬嵪嵐愎䆪㉥⋌ɿ  
㓈ᡸꢀꢀㆁ㙊丵Ἧ⼆枼䑲嫥嬂䗅丵Ἧ᷻⎙弜垍ɿꢀ嫿⡈⃆  
怩㯢㙊䑩ㅸ⌰Ḧ㘵㊣䗅昷ḷɿ忀₎℻䋱大䑶⊲斪  
ᵎ壂儫ⴲ嬖☿㆔⹁嫿⡈䘗⪑丵Ἧ嬦嫿⡈ɿ  
⊼ᛣ  
䯙䇏䇈ᯢкꢀ䑩ㅸỀ䑩嬦嫿⡈↎⼆枼敆嬼⶷䍇夤ㆁ㙊  
⫊₩⏍Ề䑩嬵㕏ɿ  
䗮亢ᄨꢀ㙊ᷜ嫿⡈㙻⠴ᵋ㙊彛栏㤾ㅗ⪕ḭ㕰䑩㚦  
敳㪣㙻⃆㒐だ₄ḷ弈䀮ɿꢀᵎ壂䑩Ḽẖᵝ壀㉢Ẑ彛  
栏⪕ɿ  
ֱᄬ䇈ᯢкꢀ䑩ㅸⷕ἞⪙⫊₩嬵㕏ᶧḦ⡈⭇㚦Ề䑩ɿ  
䙉ᅜ䄺ਞꢀ䑩ㅸⷕ徶⫉ᷨ␂⏍䑩ㅸ㉈⊘ᵋ䗅ㆁ㙊⫊₩  
⏍㐎ẝ嬵㕏ɿ  
䫖⬉∴ꢀᵎ㪤䞯䗅㘵㊣䑶㮡ṛ㙊䅇㿹䗅⊲斪ɿ枼Ề䑩  
ᵏ⋃⫷㋩劑䗅䘹⍍ㅗ䘹弒⛌⌸䗅䑶㮡ɿ䂨䑠ᷨ⋃  
䗅⸻嫯⡅䍇ⷠ⹄䑶㮡ɿ  
ܡ
ᵎ壂Ề䑩嬦ᷨ␂⋃⒇㯢㙊㋩劑䗅⴦₸ㅗ弾  
⇡嫿忀₎⊲斪ɿ  
 
Table of Contents  
Chapter One • Introduction ................................................... 1-1  
About this Manual .................................................................... 1-2  
About the YCS SW2.................................................................. 1-2  
Features ........................................................................................ 1-2  
Application Diagrams............................................................... 1-4  
Chapter Two • Installation Overview.............................. 2-2  
Mounting the YCS SW2........................................................... 2-2  
Tabletop use........................................................................... 2-2  
Rack mounting....................................................................... 2-3  
Mounting on a standard or VersaTools rack shelf ........ 2-3  
Back of the rack mounting .............................................. 2-5  
Furniture mounting ............................................................... 2-6  
Projector mounting................................................................ 2-7  
PMK 100 Mini Projector Mount Kit................................. 2-7  
PMK 250 Projector Mount Kit.......................................... 2-8  
PMK 300 Projector Mount Kit........................................ 2-10  
Rear Panel Features ................................................................ 2-11  
Wiring the Power Connector............................................... 2-12  
Wiring the Captive Screw Connector................................ 2-13  
Contact Closure........................................................................ 2-14  
Autoswitching .......................................................................... 2-14  
Front Panel Features............................................................... 2-15  
Selecting an Input by Using the Buttons......................... 2-16  
Appendix A • Specifications, Part Numbers, and  
Accessories ........................................................................................A-1  
Specifications..............................................................................A-2  
Included Parts .............................................................................A-4  
Accessories...................................................................................A-4  
All trademarks mentioned in this manual are the properties of their respective owners.  
68-1110-01 Rev. A  
09 05  
YCS SW2 • Table of Contents  
i
 
Table of Contents, cont’d  
YCS SW2  
Chapter One  
1
Introduction  
About this Manual  
About the YCS SW2  
Features  
Application Diagrams  
ii  
YCS SW2 • Table of Contents  
 
Introduction  
Digital time base correction — Time base correction stabilizes  
the video signal in the time domain. This results in a  
significantly more stable image on the screen and better  
recording quality from input sources with unstable video  
signals, such as consumer VCRs and worn or multi-  
generation VHS tapes.  
About this Manual  
This manual contains information about the Extron YCS SW2  
Switcher, and discusses how to install, configure, and operate it.  
The terms “YCS SW2,” “YCS,” and “Switcher” are used  
interchangeably throughout this manual.  
Simultaneous composite video and S-video outputs — One  
composite video and two S-video outputs allow for  
recording and display at the same time.  
About the YCS SW2  
The Extron YCS SW2 is a high-performance, two input  
(one composite video and one S-video) switcher with three  
simultaneous outputs (one composite video and two S-video),  
digital transcoding and autoswitching capabilities, and digital  
time base correction (TBC). Using a 3-line NTSC/5-line PAL  
digital comb filter, the YCS accepts NTSC 3.58, NTSC 4.43, PAL,  
or SECAM composite video, and decodes the signal into Y  
(luma) and C (chroma) for S-video. As an encoder, it combines  
Y and C signals and outputs a composite video image.  
Individually buffered S-video outputs — Two individually  
buffered S-video outputs are provided on one female  
4-pin mini DIN connector and a pair of female BNC  
connectors, for easy integration.  
Contact closure remote control — Inputs can be selected  
remotely using a user-supplied two-button contact closure  
device.  
Quad standard compatibility — The digital quad standard  
Certain projectors have both video and S-video inputs, but  
can use only one of them at a time. The YCS SW2 solves this  
problem by autoswitching between composite video and  
S-video, then decoding the S-video to feed to the projector. (See  
figure 1-1 under Application Diagrams, later in this chapter.)  
decoder/encoder provides for universal compatibility.  
Enclosure — The YCS SW2 has a compact 1U high, ¼-rack  
wide, 3 inches deep Versatools® metal enclosure that can  
be easily placed or mounted in a variety of locations.  
The YCS SW2 can also be used at the output of a multi-format  
switcher, such as the Extron MPS 112, to automatically select  
between the video and S-video group outputs, sending a single  
S-video signal to the projector. (See figure 1-2.)  
Power supply — An external 12 VDC power supply with a  
two-pin captive screw connector accepts 100 to 240 VAC.  
Rack and furniture mounting — The YCS SW2 can be mounted  
on a rack shelf, under a desk or podium, or on a projector  
pole, with an optional mounting kit.  
Inputs can be selected by pressing the front panel buttons, by  
enabling autoswitching using a jumper wire, or by contact  
closure using a remote push-button device.  
Features  
Autoswitching — The YCS SW2 can be configured to  
automatically switch to the active input when the  
YCS detects a video signal, thus providing hands-free  
switching. If both the composite video and the S-video  
signals are present, the switcher defaults to input 2,  
S-video.  
Digital encoding and decoding — The YCS SW2 digitally  
decodes (separates) the composite video input signal into  
Y and C for S-video, and encodes (combines) the Y and C  
signals of S-video input into composite video.  
YCS SW2 • Introduction  
YCS SW2 • Introduction  
1-2  
1-3  
 
Introduction, cont’d  
Application Diagrams  
YCS SW2  
The following diagrams provide examples of how the YCS SW2  
may be connected.  
VCR  
Projector  
S-video  
Camera  
Video  
Extron  
S-video  
2
YCS SW2  
W
S
S
C
Y
Two Input, Three Output  
Transcoding Switcher  
W
-S  
O
T
U
T
A
U
P
T
C
T
A
T
U
O
N
O
C
S
2
T
U
1
P
N
I
C
R
E
POW  
X
A
V
2
1
0
A
M
.3  
2
Video  
Chapter Two  
VCR  
Figure 1-1 — Connecting the YCS SW2 to a single-  
video-input projector and two input devices  
2
Extron  
MPS 112CS  
Media Presentation  
Switcher  
2
1
1
S
P
M
T
U
)
O
R
O
G
RO  
P
E
ID  
OU  
(V  
L
4
2
Installation and Operation  
)
O
E
ID  
O
-V  
(S  
4
3
2
I
O
U
T
A
U
L
O
1
)
A
G
(V  
M
O
T
N
A
W
O
I
C
R
R
E
3
4
H
P
IN  
P
2
M
3
-2  
S
1
R
2
A
G
V
T
O
Installation Overview  
1
2
O
E
ID  
V
X
A
M
0A  
0.  
O
E
ID  
0V  
24  
0-  
-
V
10  
S
1
S-video  
Projector  
z
H
0
/6  
50  
Mounting the YCS SW2  
Video  
Rear Panel Features  
S-video  
2
Extron  
YCS SW2  
Video Decoder/  
Switcher/TBC  
W
S
S
C
Y
Wiring the Power Connector  
Wiring the Captive Screw Connector  
Contact Closure  
W
-S  
O
T
U
T
A
U
P
T
C
T
A
U
T
N
O
O
C
S
2
T
U
1
P
N
I
WER  
X
PO  
V
A
A
M
2
1
0
3
2
.
Figure 1-2 — Connecting the YCS SW2 to a multi-  
format switcher  
Autoswitching  
Front Panel Features  
Selecting an Input by Using the Buttons  
YCS SW2 • Introduction  
1-4  
 
Installation and Operation  
Rack mounting  
Installation Overview  
For optional rack mounting, do not install the rubber feet.  
To install and set up the YCS SW2, follow these steps:  
Mount the switcher on a 19” wide 1U VersaTools® rack shelf  
(Extron part #60-190-20 or 60-604-20), a standard 1U Universal  
or Basic rack shelf (Extron part #60-190-01 or 60-604-01), or  
a Universal or Basic 1U 6-inch Deep Rack Shelf (Extron part  
#60-190-10 or 60-604-10).  
Mount the YCS SW2 on a rack shelf, furniture, or projector  
if desired.  
1
Connect your composite video and/or S-video input  
source(s) to one or both YCS input connectors.  
2
3
Mounting on a standard or VersaTools rack shelf  
Connect your output device(s) to the YCS composite video  
and/or S-video output connector(s).  
1.  
If feet were previously attached to the bottom of the YCS,  
remove them.  
Wire the provided 2-pin captive screw connector to the  
external power supply. (See Wiring the Power Connector,  
later in this chapter.)  
4
5
2.  
Mount the YCS SW2 on the rack shelf, using two 4-40 x  
3/16” screws in opposite (diagonal) corners to secure the  
unit to the shelf (see figure 2-1, below).  
If using autoswitching, insert the provided 5-pin captive  
screw plug into the 5-pin connector on the YCS back  
panel, and jumper-connect pins 4 and 5 together. (See  
Autoswitching, later in this chapter.)  
3.  
Install blank panel(s) or other unit(s) on the rack shelf as  
desired.  
VersaTools Rack Shelf  
If using contact closure for input selection, connect a two-  
button remote contact closure device to pins 1, 2, and 3 of  
the captive screw connector on the YCS rear panel. (See  
Contact Closure, later in this chapter.)  
6
7
Apply power to the YCS SW2 and to the input and output  
devices.  
Mounting the YCS SW2  
1/4 Rack Width Front  
False Faceplate  
The YCS SW2 can be set on a table; mounted on a rack shelf;  
mounted under a desk, podium, or table; or attached to a  
projector.  
Tabletop use  
Use 2 mounting holes on  
opposite corners.  
Four self-adhesive rubber feet are included with the YCS SW2.  
For tabletop use, attach one foot at each corner on the bottom of  
the unit, and place the YCS in the desired location.  
(2) 4-40 x 3/16"  
Screws  
Figure 2-1 — Mounting a YCS SW2 (with other  
units) on a VersaTools rack shelf  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-2  
2-3  
 
Installation and Operation, cont’d  
Back of the rack mounting  
The YCS SW2 also can be mounted vertically to the front or rear  
rack supports, using the optional back of the rack mounting kit  
(Extron part #70-367-01).  
1U Universal Rack Shelf  
1/2 Rack Width Front False  
Faceplate  
1/4 Rack Width Front False  
Faceplate  
Follow these steps to mount the YCS to the rack supports using  
the back of the rack mounting kit:  
1.  
2.  
3.  
4.  
If feet were previously attached to the bottom of the YCS,  
remove them.  
Remove the two screws from one side of the YCS. Retain  
the screws for possible later reassembly.  
Both front false faceplates  
use 2 screws.  
Attach one bracket to the side of the unit, using the longer  
screws included in the mounting kit (see figure 2-4, below).  
Repeat steps 2 and 3 on the other side of the YCS.  
(2) 4-40 x 3/16"  
Screws  
Use 2 mounting holes on  
opposite corners.  
Figure 2-2 — Mounting a YCS SW2 on a standard  
rack shelf  
6" Deep Rack Shelf  
1/2 Rack Width Front False  
Faceplate  
Figure 2-4 — Attaching the back of rack mounting  
brackets to the YCS SW2  
Front false  
faceplate  
uses 2  
screws.  
5.  
Mount the unit to the rack support, using the two included  
rack screws.  
(2) 4-40 x 3/16"  
Screws  
Use 2 mounting holes on  
opposite corners.  
Figure 2-3 — Mounting a YCS on a 6-inch rack shelf  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-4  
2-5  
 
Installation and Operation, cont’d  
4.  
5.  
Repeat steps 2 and 3 on the other side of the YCS.  
Hold the unit with the attached brackets against the  
underside of the table or other furniture. On the mounting  
surface, mark the location of the bracket’s screw holes.  
6.  
7.  
Drill 3/32” (2 mm) diameter pilot holes, ¼” (6.3 mm) deep  
in the mounting surface at the marked screw locations.  
1
L
A
U
2
L
D
IN  
P
I
U
T
S
T
3
L
S
R
M
LS  
L
103  
V
4
R
A
U
M
X
/
M
I
O
U
O
N
T
O
P
P
U
T
R
L
EA  
M
P
2
R
M
W
S
L
P
C
O
/R  
W
S
-2  
R
3
S
E
2
C
Y
12  
A
V
B
1
.5A  
M
L
A
1
X
A
U
2
L
DI  
IN  
P
U
R
2
Insert #8 wood screws into the four pilot holes. Tighten  
each screw into the mounting surface until slightly less  
than ¼” of the screw head protrudes.  
O
R
U  
T
S
T
3
L
S
M
L
S
L
103  
V
4
R
A
U
M
X
/
M
I
X
O
U
O
N
T
O
P
P
U
T
R
L
EA  
1
M
P
R
M
L
P
C
O
/R  
W
S
-2  
R
3
E
2
12  
A
B
O
T
H
C
V
U
A
I
T
.5A  
M
W
S
A
X
1
L
1
R
A
U
L
DI  
N  
S
2
P
U
T
S
T
3
L
M
R
LS  
L
103  
R
A
U
M
V
X
M
/
N
I
O
U
O
T
P
P
U
T
R
L
EA  
M
P
8.  
9.  
Align the mounting screws with the slots in the brackets  
and place the unit against the surface, with the screws  
through the bracket slots.  
R
M
L
P
C
O
/R  
W
S
-2  
R
3
2
E
1
O
U
T
12V  
A
P
2
B
U
T
1
.5  
A
MA  
X
3
1
O
U
T
P
2
U
T
2
3
M
M
X
32  
V
G
A
A
Slide the unit slightly forward or back, then tighten all four  
screws to secure it in place.  
Projector mounting  
Figure 2-5 — Mounting the YCS SW2 to a back rack  
support  
To projector-mount the YCS SW2, three optional mounting kits  
are available for use with the YCS SW2.  
PMK 100 Mini Projector Mount Kit  
Furniture mounting  
The PMK 100 is a projector mounting kit (part # 70-217-01)  
designed for use with Extron 1U high, quarter-rack width  
products like the VersaTools products. It allows them to be  
mounted near or on a projector support.  
To furniture-mount the YCS SW2, use the optional VersaTools  
under-desk mounting kit (part #70-212-01), as follows.  
1.  
2.  
3.  
If rubber feet were previously attached to the bottom of the  
unit, remove them.  
Follow these steps to projector-mount the YCS SW2 using the  
PMK 100 kit:  
Remove the two screws from one side of the YCS. Retain  
the screws for possible later reassembly.  
1.  
2.  
3.  
If rubber feet were previously attached to the bottom of the  
unit, remove them.  
Attach one bracket to the side of the unit, using the  
provided machine screws (see figure 2-6, below).  
Remove the two screws from one side of the YCS. Retain  
the screws for possible later reassembly.  
Attach the projector mounting bracket to the side of the  
unit, using the provided machine screws.  
Figure 2-6 — Preparing the YCS SW2 for under-desk  
mounting  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-6  
2-7  
 
Installation and Operation, cont’d  
Rubber Pad  
U-bolt  
Mounting  
Bolt  
Mounted  
Extron Product  
Projector  
Mounting  
Bracket  
Extron  
PMK 250  
Projector Mount Kit  
Ceiling  
Plastic Tie  
Projector  
Front Plate  
Extron  
Power Supply  
Figure 2-7 — Projector-mounting the YCS SW2 using  
the PMK 100 Projector Mount kit  
Cover Sheet  
4.  
Secure the unit to a projector mount or other surface by  
inserting the mounting bolt through the bracket’s slotted  
hole.  
Figure 2-8 — Projector-mounting the YCS SW2 using  
the PMK 250 Projector Mount Kit  
PMK 250 Projector Mount Kit  
7.  
Insert the two legs of the provided square U-bolt through  
the slotted holes on the back side of the bracket mount  
plate, place the two legs around the ceiling pole, then  
insert them through the round holes on the backing brace.  
The PMK 250 Low Profile Projector Mount Kit is an above-  
projector mounting kit that attaches to a 1” to 2” diameter  
projector mounting pole. It can hold more than one device,  
in a variety of sizes. The PMK 250 is available in black (part  
#70-526-02) or white (part #70-526-03).  
For a typical (1.5” to 2.0” diameter) pole You can  
use the supplied square U-bolt, which fits a typical  
ceiling pole.  
Follow these steps to mount the YCS SW2 on the PMK 250  
bracket as follows:  
For a smaller pole — Locally obtain a square U-bolt  
that fits your ceiling pole. The slotted holes on the  
bracket can accomodate a square U-bolt for pole sizes  
from 1.0” to 2.0” in diameter.  
1.  
Remove the front panel from the PMK 250, using an Extron  
Tweeker or other small Philips screwdriver. (Retain the  
four screws to reattach the plate when finished.)  
2.  
Remove the protective backing from the self-adhesive  
rubber pad, and place the pad on the PMK 250 mount  
plate, centering it between the two holes (see figure 2-8).  
8.  
9.  
Move the PMK 250 up to the desired location on the ceiling  
pole, as close to the ceiling as desired.  
Secure the back brace to the square U-bolt using the  
included hex nuts, washers, and lock washers. Tighten the  
hex nuts securely.  
3.  
4.  
Remove any rubber feet from the bottom of the YCS SW2.  
Secure the YCS to one side of the mounting bracket,  
using two of the supplied 4-40 x 3/16 screws in opposite  
(diagonal) corners.  
Be sure to tighten the hex nuts securely enough that the  
PMK 250 does not slide down the ceiling pole. A socket  
wrench is recommended to tighten the hex nuts.  
5.  
6.  
Using the two included tie wraps, strap the YCS power  
supply to the PMK 250 bracket.  
10. Secure the front panel to the mounting tray with four of  
Place the bracket around the projector ceiling mounting  
pole as shown in figure 2-8.  
the included #6 screws.  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-8  
2-9  
 
Installation and Operation, cont’d  
11. If desired, choose one of the provided four sizes of self-  
adhesive cover sheets, and apply it to the underside of the  
mounting tray.  
Rubber Pad  
PMK 300 Projector Mount Kit  
The PMK 300 Multi-Product Projector Mount Kit (#70-374-01)  
mounts up to three quarter-rack width products to a projector  
ceiling mount pole. The YCS SW2 can be mounted above the  
display device with the front panel facing either down or up.  
The quarter rack width plate can also be used to mount the YCS  
external desktop power supply.  
Multi Product  
Projector Mounting Kit  
U-Bolt  
Follow these steps to projector-mount the YCS SW2 using the  
PMK 300:  
1.  
2.  
If necessary, remove the feet from the bottom of the YCS.  
Mount the YCS to one of the bracket’s three mounting  
plates. It can be vertically mounted facing either up or  
down, whichever is most convenient. See figure 2-9.  
On the side mounting plates, the YCS is typically  
mounted on the outside of the bracket.  
Figure 2-9 — Projector-mounting the YCS SW2 using  
the PMK 300 Projector Mount Kit  
On the front mounting plate, the device is typically  
mounted on the inside of the bracket.  
For the YCS SW2 unit, use two of the supplied 4-40 x  
3/16 screws in opposite (diagonal) corners to secure  
the device to the bracket.  
Rear Panel Features  
For the YCS power supply, use the two included tie  
wraps to strap the power supply to the bracket.  
6
4
2
3.  
Place the U-bolt around the ceiling pole and insert the two  
legs of the U-bolt through the slotted holes on the bracket’s  
mounting plate, then through the round holes on the  
backing brace.  
INPUTS  
OUTPUT  
YCS SW2  
POWER  
12V  
0.3A MAX  
1
2
Y
C
VIDEO  
CONTACT AUTO-SW  
1
7
For a typical (1.5” to 2.0” diameter) pole You can  
use the supplied square U-bolt, which fits a typical  
ceiling pole.  
1
2
S-VIDEO  
3
5
For a smaller or larger pole — Locally obtain a square  
U-bolt that fits your ceiling pole. The slotted holes on  
the bracket can accomodate a square U-bolt for pole  
sizes from 1.0” to 2.5” in diameter.  
Figure 2-10 — YCS SW2 rear panel  
1
2
3
Power connector — Plug the external 12 VDC power supply  
into this 2-pin, 3.5 mm captive screw connector.  
4.  
Secure the bracket to the U-bolt with the included hex  
nuts, washers, and lock washers. Tighten the hex nuts just  
enough that they can be loosened by hand.  
Input 1 connector — Connect a composite video input source to  
this BNC connector.  
Input 2 connector — Connect an S-video input source to this  
4-pin mini-DIN connector.  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-10  
2-11  
 
Installation and Operation, cont’d  
The figure below shows how to wire the connector.  
4
5
6
Video output connector — Connect a composite video display  
device to this BNC connector.  
Smooth  
Ridges  
S-video output connector — Connect an S-video display device  
to this female 4-pin mini-DIN connector.  
A
A
SECTION A–A  
S-video Y and C output connectors — Connect the luma (Y)  
and chroma (C) connectors of an S-video display device to these  
Y and C female BNC connectors, respectively.  
0.2” (5 mm)  
Power Supply  
Output Cord  
7
Autoswitching and contact closure connector — This 5-pin,  
3.5 mm captive screw connector can be used for autoswitching  
and for control by contact closure.  
Captive Screw  
Connector  
Connect an optional two-button contact closure device to  
the three ports labeled “Contact” (pins 1, 2, and 3). (See  
Contact closure, later in this chapter.)  
Figure 2-11 — Power connector wiring  
CAUTION  
Do not tin the stripped power supply leads before  
attaching the captive screw plug to them. Tinned  
wires are not as secure in the captive screw  
connectors and can be easily pulled out. They may  
also break after being bent several times.  
Jumper-wire together the two ports labeled “Auto-SW”  
(pins 4 and 5) to enable autoswitching. (See Autoswitching,  
later in this chapter.)  
The two power cord wires must be kept separate  
while the power supply is plugged in. Remove  
power before wiring.  
Wiring the Power Connector  
To wire the connector for the external power supply,  
1.  
2.  
Cut the DC output cord to the length needed.  
Strip the jacket to expose 0.2 inches (5 mm) of the  
conductors.  
Wiring the Captive Screw Connector  
The 5-pin, 3.5 mm captive screw connector is used for optional  
push-button remote control of the YCS SW2, and/or to enable  
autoswitching between inputs connected to the YCS. The  
following figure shows the pin assignments for the captive  
screw connector.  
CAUTION  
Exposing more than 0.2” (5 mm) of the copper  
wires could allow the stripped wires to touch each  
other, causing a short circuit. This could result in  
the external DC power supply overheating and/or  
burning.  
AUTO-SW  
CONTACT  
Stripping the wires to expose less than the  
recommended amount may cause them to slide out  
of the connector too easily, even if they are tightly  
pinched by the captive screws.  
1
2
(1) (2) (3) (4) (5)  
Auto-  
switch  
Contact  
3.  
4.  
Slide the leads into the supplied 2-pin captive screw plug  
and secure them, using an Extron Tweeker or other small  
screwdriver.  
PIN  
1
2
3
4
Closure  
In #1  
In #2  
Gnd  
Function  
Input #1 (contact)  
Input #2 (contact)  
Ground  
Autoswitching  
Autoswitching  
Gnd  
To Pin 5  
To Pin 4  
To verify the power cord’s polarity before connecting  
it, plug in the power supply with no load and check the  
output with a voltmeter.  
5
Figure 2-12 — Captive screw connector pin  
assignments  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-12  
2-13  
 
Installation and Operation, cont’d  
Contact Closure  
2.  
Insert the plug into the 5-pin captive screw connector on  
the YCS rear panel.  
Pins 1, 2, and 3 of the captive screw connector enable input  
switching via a latching contact closure device.  
If you want to select inputs remotely, you can connect a two-  
button contact closure device to pins 1, 2, and 3 of the rear  
panel captive screw connector. When a contact closure device  
is connected, the front panel input selection buttons remain  
functional as well.  
2
W
S
S
C
Y
W
S
-
O
T
U
A
T
C
A
T
N
OUTPUT  
O
C
S
1
INPUT  
EO  
S-VID  
ER  
W
Autoswitching  
PO  
X
2V  
1
0
MA  
2
A
.3  
You can set up the YCS to automatically select the active,  
connected input. If both inputs are active, selection defaults to  
input 2 (S-video). You enable autoswitching by connecting pins  
4 and 5 of the rear panel captive screw connector with a small  
piece of wire that functions as a jumper. Autoswitching remains  
in effect as long as the jumper wire is connecting these two pins  
together.  
Figure 2-14 — 5-pin captive screw plug in rear  
panel, with pins 4 and 5 connected by a jumper  
Front Panel Features  
When autoswitching is in effect, the green Auto Switch LED on  
the front panel lights, and the front panel input selection buttons  
are disabled.  
2
3
5
4
1
To enable autoswitching, do the following:  
1.  
Cut a small piece of wire to use as a jumper, and insert the  
ends of the wire into pin holes 4 and 5 of the provided  
5-pin captive screw plug, connecting pins 4 and 5 together  
as shown in figure 2-13, below. Use an Extron Tweeker or  
other small screwdriver to tighten the plug’s pin 4 and 5  
screws, so that the wire ends remain securely in place.  
AUTO  
SWITCH  
1
2
YCS SW2  
VIDEO DECODER / ENCODER / SWITCHER  
Figure 2-15 — YCS SW2 front panel  
The YCS SW2 front panel contains the following:  
1
Auto Switch LED — This green LED lights when autoswitching  
is enabled. When this LED is lit, the Input Selection buttons  
are disabled (although their indicator LEDs continue to light  
to indicate which input has been selected). See Autoswitching,  
earlier in this chapter, for the procedure to set up autoswitching.  
2
3
4
5
Input 1 Selection button — Press this button to select input 1,  
composite video.  
Figure 2-13 — Captive screw plug with a jumper  
wire connecting pins 4 and 5 together  
Input 1 indicator LED — This green LED lights when input 1  
has been selected.  
Input 2 Selection button — Press this button to select input 2,  
S-video.  
Input 2 indicator LED — This green LED lights when input 2  
has been selected.  
YCS SW2 • Installation and Operation  
YCS SW2 • Installation and Operation  
2-14  
2-15  
 
Installation and Operation, cont’d  
Selecting an Input by Using the Buttons  
YCS SW2  
The YCS SW2 has two inputs available — one composite  
video and one S-video. You can select either of these inputs by  
pressing the appropriate button on the front panel. When an  
input is selected, its LED lights and remains lit while its input  
source is active.  
The front panel buttons are labeled “1” and “2” for the two  
inputs. Press input button 1 to select the composite video input,  
or button 2 to select the S-video input.  
You can also set up the YCS to select inputs via contact closure  
or autoswitching. For information on enabling input selection  
by either of these methods, see Contact closure or Autoswitching,  
earlier in this chapter.  
The YCS SW2 does not have non-volatile memory.  
Therefore, the input selection defaults to input 1 after a  
power loss.  
Appendix A  
A
Specifications, Part Numbers,  
and Accessories  
Specifications  
Included Parts  
Accessories  
YCS SW2 • Installation and Operation  
2-16  
 
Specifications, Part Numbers, and Accessories  
General  
Specifications  
External power supply................. 100 VAC to 240 VAC, 50/60 Hz, external,  
autoswitchable; to 12 VDC, 1 A, regulated  
Power input requirements........... 12 VDC, 0.3 A  
Temperature/humidity................ Storage: -40 to +158 °F (-40 to +70 °C) /  
10% to 90%, noncondensing  
Video  
Gain ................................................ Unity  
Bandwidth...................................... 5 MHz (-3 dB)  
Switching speed ............................ 5 ms (max.)  
Operating: +32 to +122 °F (0 to +50 °C) /  
10% to 90%, noncondensing  
Standards........................................ NTSC 3.58, NTSC 4.43, PAL, PAL-N,  
SECAM; autodetected  
Rack mount.................................... Yes, with optional rack shelf:  
1U rack shelf, part #60-190-01 or 60-604-01;  
IU, 6” deep rack shelf, part #60-190-10 or  
60-604-10;  
Crosstalk......................................... 60 dB @ 3.58 MHz  
Video input  
Number/signal type..................... 1 S-video, 1 composite video  
Connectors ..................................... 1 female 4-pin mini DIN and 1 female  
BNC  
Nominal level ................................ 1 Vp-p for Y of S-video and for composite  
video  
0.3 Vp-p for C of S-video  
Minimum/maximum levels........ Analog: 0.3 V to 1.5 Vp-p for video and Y  
with no offset at unity gain  
VersaTools® rack shelf, part #60-190-20 or  
60-604-20.  
Furniture mountable with optional  
VersaTools Under-Desk Mounting Kit,  
#70-212-01  
Projector mountable with optional  
projector mount kit:  
PMK 100 Mini Projector Mount Kit  
#70-217-01  
Impedance ..................................... 75 ohms  
PMK 250 Low Profile Projector Mount Kit  
#70-526-02, -03  
PMK 300 Multi-Product Projector Mount  
Kit #70-374-01  
Return loss ..................................... Composite video –34 dB, Y –27 dB,  
C -31 dB @ 5 MHz  
DC offset (max. allowable) .......... 5.0 V  
Input coupling............................... AC coupled  
Enclosure type .............................. Metal  
Enclosure dimensions .................. 1.7” H x 4.3” W x 3.0” D (1U high, quarter  
rack wide)  
4.3 cm H x 10.9 cm W x 7.6 cm D  
(Depth excludes connectors.)  
Product weight .............................. 0.4 lbs (0.2 kg)  
Shipping weight ........................... 3 lbs (2 kg)  
Vibration ........................................ ISTA 1A in carton (International Safe  
Transit Association)  
Listings ........................................... UL, CUL  
Compliances................................... CE, FCC Class A, VCCI, AS/NZS, ICES  
MTBF............................................... 30,000 hours  
Warranty ........................................ 3 years parts and labor  
Video output  
Number/signal type..................... 2 S-video, 1 composite video  
Connectors ..................................... 2 female BNC and/or 1 female 4-pin mini  
DIN for S-video  
1 female BNC for composite video  
Nominal level ................................ 1 Vp-p for Y of S-video and for composite  
video  
0.3 Vp-p for C of S-video  
Minimum/maximum levels........ 0.3 V to 1.5 Vp-p for video and Y  
Impedance ..................................... 75 ohms  
Return loss ..................................... -40 dB @ 3.58 MHz  
Control/remote  
All nominal levels are at 10%.  
Contact closure .............................. 1 female captive screw connector, 5 pole  
Specifications are subject to change without notice.  
Contact closure pin configurations  
1 = input 1, 2 = input 2, 3 = GND,  
4 and 5 = autoswitch selection  
YCS SW2 • Specifications, Part Numbers, and Accessories  
YCS SW2 • Specifications, Part Numbers, and Accessories  
A-2  
A-3  
 
Specifications, Part Numbers, Accessories, cont’d  
Included Parts  
These items are included in each order for a YCS SW2:  
Included parts  
Part numbers  
to reorder  
YCS SW2 switcher  
60-757-01  
12 VDC, 1A external power supply  
with U. S. style power cord  
70-055-01  
2-pin captive screw power plug  
5-pin captive screw plug  
YCS SW2 User's Manual  
Rubber feet, self-adhesive (4, not attached)  
Tweeker (small screwdriver)  
Accessories  
These items are optional and may be ordered separately:  
Accessories  
Part numbers  
19" 1U Universal rack shelf  
60-190-01  
or  
60-604-01  
1U 6" Deep Universal rack shelf  
1U VersaTools® rack shelf  
60-190-10  
or  
60-604-10  
60-190-20  
or  
60-604-20  
Back of the rack mounting kit  
70-367-01  
70-212-01  
70-217-01  
Under-desk mounting bracket kit  
PMK 100 Mini Projector Mount Kit  
PMK 250 Low Profile Projector Mount Kit 70-526-02, -03  
PMK 300 Multi-Product Projector Mount  
Kit  
70-374-01  
26-260-xx  
26-316-xx  
Mini HR cables  
S-video cables  
S-video adapters: SVHSMF-BNCF, 8” (0.2 m) 26-353-01  
YCS SW2 • Specifications, Part Numbers, and Accessories  
A-4  
 

Electro Voice Stereo Amplifier E V 44 User Manual
Euro Pro Carpet Cleaner SC618HD User Manual
Frymaster Fryer D160G User Manual
Garmin GPS Receiver 190 00004 00 User Manual
GE Cooktop JGP630ER User Manual
GE Cordless Telephone 00028056 User Manual
GE Fax Machine D780 User Manual
Generac Portable Generator 5500EXL User Manual
Generac Power Systems Portable Generator 009600 5 009734 5 User Manual
GMC Automobile 2010 Acadia User Manual