Furuno Radar Detector FAR 2XX7 User Manual

FAR-2xx7 SERIES MARINE RADAR  
Operator’s Guide  
The purpose of this Operator's Guide is to provide the basic operating procedures for this equipment. For  
more detailed information, see the Operator's Manual. This manual describes operating procedures using  
the trackball module, since it is common to both types of control units.  
A/C RAIN  
A/C SEA  
BRILL  
GAIN  
F1  
F2  
F3  
F4  
OFF  
ON  
OFF  
ON  
1
HL  
OFF  
2
EBL  
OFFSET  
3
EBL  
VRM  
MODE  
4
OFF  
CENTER  
5
6
CU/TM  
RESET  
ACQ  
Trackball  
Module  
F1  
F3  
F2  
F4  
INDEX  
LINE  
MENU  
7
8
9
TARGET  
DATA  
+
VECTOR  
TIME  
VECTOR  
MODE  
TARGET  
LIST  
RANGE  
0
TARGET  
CANCEL  
ALARM  
ACK  
STBY  
TX  
CANCEL  
TRAILS  
ENTER  
MARK  
-
BRILL  
RCU-014  
RCU-015  
Trackball  
Module  
Control  
POWER  
EBL and VRM controls Adjust EBL and VRM, respectively.  
Description  
Turns the system on and off.  
EBL ON, EBL OFF  
VRM ON, VRM OFF  
F1-F4  
ALARM ACK  
STBY TX  
Turns the EBLs on and off, respectively.  
Turns the VRMs on and off, respectively  
Execute menu short cut assigned.  
Silences audible alarm.  
Toggles between stand-by and transmit.  
BRILL  
A/C RAIN  
Adjusts screen brilliance of FURUNO-supplied monitor.  
Suppresses rain clutter.  
A/C SEA  
Suppresses sea clutter.  
GAIN  
HL OFF  
Adjusts sensitivity of the radar receiver.  
Temporarily erases the heading line while pressed.  
EBL OFFSET  
MODE  
Enables, disables the EBL offset. Switches coordinate polarity (menu operation).  
Chooses presentation mode.  
OFF CENTER  
CU/TM RESET  
Shifts own ship position.  
Moves own ship position in 75% radius in stern direction.  
Resets the heading line to 0° in course-up and true motion modes.  
Turns index lines on and off.  
Chooses vector time (length).  
Chooses vector mode, relative or true.  
Displays ARP target list.  
Cancels all target trails. In menu operation it clears line of data.  
Chooses color scheme.  
INDEX LINE  
VECTOR TIME  
VECTOR MODE  
TARGET LIST  
CANCEL TRAILS  
BRILL/O  
ENTER MARK  
MENU  
ACQ  
Enters marks; terminates keyboard input.  
Opens and closes the MAIN menu; closes other menus.  
- Acquires a target for ARP.  
- Changes a sleeping AIS target to an activated one.  
Chooses radar range.  
RANGE  
TARGET DATA  
TARGET CANCEL  
Displays target data for ARP or AIS target chosen with the trackball.  
Cancels tracking on ARP, AIS or reference target chosen with the trackball.  
 
Manual Tuning  
Adjusting A/C RAIN  
1. Choose the RANGE box and then push  
the left or right button as appropriate to  
choose the 48-mile range.  
2. If using automatic tuning, choose TUNE  
AUTO at the top of the screen and then  
push the left button to show TUNE MAN.  
3. Place the arrow on the tuning bar area in  
the TUNE box.  
1. Place the cursor in the A/C RAIN level  
indicator.  
2. Roll the wheel downward to increase the  
A/C RAIN or upward to decrease it.  
Suppressing Interference  
1. Choose the PICTURE box.  
2. Push the right button to show the  
PICTURE menu.  
3. Choose 1 INT REJECT and then push the  
wheel.  
4. Roll the wheel to adjust tuning. The best  
tuning point is where the bar graph swings  
maximum.  
4. Choose rejection level desired and then  
push the wheel.  
Choosing a Display Mode  
1. Choose the DISPLAY MODE box.  
2. Push the left button to choose appropriate  
mode: radar or radar + plotter.  
5. Push the right button to close the menu.  
Measuring the Range  
1. Place the arrow in the VRM1 or VRM2  
box.  
Choosing a Presentation Mode  
1. Choose the PRESENTATION MODE box.  
2. Push the left button to choose desired  
mode.  
2. Push the left button to turn on the VRM.  
3. Push the left button again.  
4. Roll the trackball (coarse adjustment) or  
wheel (fine adjustment) to align the active  
variable range marker with the inner edge  
of the target of interest.  
Choosing a Range  
1. Choose the RANGE box.  
2. Push the right or left button to change the  
range.  
To erase a VRM, choose the appropriate  
VRM readout box and then push the left  
button until the VRM disappears from the  
screen.  
Adjusting Sensitivity  
1. Choose the gain level indicator.  
2. Roll the wheel downward to increase the  
gain or upward to decrease it.  
Measuring the Bearing  
1. Choose the EBL1 or EBL2 box.  
2. Push the left button.  
3. Push the left button again.  
4. Roll the trackball (coarse adjustment) or  
wheel (fine adjustment) to bisect the target  
with the EBL.  
Automatic Adjustment of Sea  
Clutter  
1. If using manual sea clutter, choose SEA  
MAN and then push the left button to show  
SEA AUTO.  
2. Place the arrow in the A/C SEA level  
indicator.  
To erase an EBL, choose the appropriate  
EBL readout box and then push the left  
button until the EBL disappears from the  
screen.  
3. Roll the wheel downward to increase the  
A/C SEA or upward to decrease it.  
3
 
<ARP OPERATION>  
Adjusting Symbol Brilliance  
Activating, Deactivating ARP  
1. Choose the BRILL box and then push the  
right button.  
2. Choose 0 NEXT and then push the wheel  
or the left button.  
1. Choose the ARP ACQ MODE box.  
2. Push the left button to show OFF, MAN or  
AUTO MAN as appropriate.  
[BRILL1 MENU (2/2)]  
Automatic Acquisition  
1 BACK  
2 BRG CURSOR  
3 EBL  
4 VRM  
1. Choose the ARP ACQ MODE box and  
then push the right button.  
2. Choose 1 ARP SELECT and then push  
the wheel or the left button.  
3. Choose automatic acquisition condition  
desired and then push the wheel or the left  
button.  
5 INDEX LINE  
6 ARP SYMBOL  
7 AIS SYMBOL  
8 L/L GRID  
9 MARK  
0 CHART  
4. Push the right button to close the menu.  
3. Choose 6 ARP SYMBOL and then push  
the wheel or the left button.  
Manual Acquisition  
4. Roll the wheel to adjust brilliance.  
5. Push the right button twice to close the  
menu.  
1. With the cursor inside the effective display  
area, roll the wheel to show “ACQ” in the  
guidance box.  
2. Place the cursor on the target you want to  
acquire.  
Vector Motion and Length  
3. Push the left button to acquire the target.  
1. Choose VECTOR TRUE or VECTOR REL  
(whichever is displayed) at the right side of  
the screen.  
2. Push the left button to display VECTOR  
TRUE or VECTOR REL as appropriate.  
3. Choose the vector time box.  
4. Push the left button to display time  
desired.  
Terminating Tracking of  
Targets  
1. With the cursor inside the effective display  
area, roll the wheel to show “TARGET  
CANCEL / EXIT” in the guidance box.  
2. Place the cursor on the ARP target or  
reference target to cancel tracking.  
3. Push the left button or the wheel.  
4. To finish, push the right button.  
CPA and TCPA Alarm Ranges  
1. Choose the CPA LIMIT box.  
2. Roll the wheel to choose the CPA value  
desired and then push the wheel.  
3. Choose the TCPA limit box.  
4. Roll the wheel to choose TCPA value  
desired and then push the wheel.  
Displaying Target Data  
1. With cursor inside the effective display  
area, roll the wheel to show “TARGET  
DATA & ACQ / CURSOR MENU” in the  
guidance box.  
2. Roll the trackball to place the cursor on a  
desired ARP target and then push the left  
button.  
P UB. NO. OS E- 3 5 1 9 0 - A  
( 0 5 0 2 , DAMI ) F AR- 2 1 0 7 / 2 8 0 7 S ERI ES  
This manual is printed with  
soy ink.  
4
 

Earthquake Sound Home Theater System PN 4521 User Manual
EdgeStar Dishwasher DWP40W User Manual
Exmark Lawn Mower 4500 471 User Manual
Exmark Lawn Mower Metro 21 Metro 26 User Manual
Fostex DVR D 160 User Manual
Fujitsu Air Conditioner Air Conditioner Wall Mounted Type User Manual
Gateway Computer Hardware ALR 9200 User Manual
GE Oven JKS06 User Manual
GE Refrigerator 197D4618P002 User Manual
Global Machinery Company Trimmer LT550 User Manual