The Digital Keyless Entry System (5 digit)
Operation User's Manual
DG-11
DG-12
DG-10
(Mount)
(Mount/ANSI size)
(Surface Mount)
ANSI Box
I. Features:
5 digit codes
Door Reed Switch Input for Anti-Trailing
10 user PINs
Fully Programmable via keypad and master code
Non-Volatile Memory
Invalid PIN Lock-out
II. Specifications:
Operating Voltage:9~14 Vdc
Current Draw: Average 30mA, Peak 80mA @ 12Vdc
Input: One request-to-exit, and time out reed switch
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc
Case Material: ABS (UL94V0)
Operating Temperature:-20~+70℃
Ambient Humidity:0~95% relative humidity non-condensing
Visual Signals:
Green: Power on
Red: Relay activated
Yellow: Program Mode、Lock-out
Factory Master Code: 12345
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly
password attempted.
Relay Activation Time: (*20)
Pulse mode:1~99 seconds(01~99)
Latching mode(00)
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
User PINs: (*01~*10)It is possible to program 10 different user PIN codes.
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG10-5C Ver. A Publish:2004.09.07
Page: 1/ 2
|