Model 100-SS
Stainless Steel Horizontal Changing Station
Installation Instructions
Thank you for purchasing a quality Foundations® product. Our goal is 100% consumer satisfaction!
If, for any reason you are not satisfied or if you have questions regarding your product or installation,
please contact our customer service team at 1-877-716-2757. Please DO NOT contact your distributor
or reseller as we are better prepared to assist you.
WARNING
•
•
Failure to follow these warnings and the installation instructions could result in serious injury
or death.
Read all instructions before installing diaper changing station. Keep these instructions. DO NOT
discard.
SI259D
INSTALLATION - RECESSED
For A. D. A. compliance, top of lower double stud should be
34 1/2"
30.5“ (78 cm) from the floor.
1"
(876 mm)
(25.4 mm)
TOP
VIEW
3 7/8"
(98.4 mm)
Recommended Blocking:
34 1/2" (876 mm)
Rough-in
Double Stud
Wood double stud blocking is necessary. Contact an architect
and building official to make sure the blocking is adequate and
complies with building codes (Fig b).
FRONT
VIEW
21 3/4"
(552 mm)
Rough-in
1. Slide changer into blocking area and mark mounting hole
location on blocking studs.
19.4"
(492 mm)
HINT: This may require 2 additional people to help hold
changer in position while you are marking the locations.
For A. D. A.
Double Stud
Compliance
30.5”
2. Shim changer for a snug fit.
(78 cm)
A. F. F
3. Align holes in changer with marked holes and secure using
Fig. b
the appropriate fasteners (Fig. c).
Recess
NOTE: It is installers responsibility to provide correct
Recess
Mounting
Holes
Mounting
Holes
fastereners for other substrates.
4. Ensure all six (6) fasteners are tight.
Recess
Mounting
Holes
Fig. c
INSTALLATION - SURFACE-MOUNT
Recommended Blocking:
Top
If the walls do not have studs on center, then additional blocking
is necessary (Fig. d).
Contact an architect or building contractor to make sure the
14”
blocking is adequate and complies with building codes.
(356 mm)
on center
For A. D. A.
Compliance
50 1/4”
For A. D. A. compliance, measure up 50 1/4” (128 cm) from the
floor and mark the wall. This locates the position for the top
left attachment hole.
(128 cm)
32"
(813 mm)
on center
A. F. F
NOTE:
- Changer MUST be mounted to studs (Fig. e).
- This unit incorporates a finishing collar that seats behind
the changer’s outside flange. Center the collar as the
unit is being tightened against the wall (Fig. f).
Fig. d
Surface-Mount
Holes
Collar
Wall
Unit
Fig. f
Fig. e
2
|